MOSFET transistor

AD5012N2LM Emerson AC-DC / External Freestanding Medical Adapter

Description Embedded Power for Business-Critical Continuity AD50 Medical Series 50 Watts Total Power: Input Voltage: # of Outputs: 50 Watts 90 - 264 VAC Single Rev. 09.19.08_108 AD50 Medical Series  of 2 RoHS Electrical Specifications Special Features • Universal AC input • Fully regulated output • EN61...
Features
• Universal AC input
• Fully regulated output
• EN61000-3-2 compliant
• Input power <74 watts
• Overcurrent and overvoltage protection
• High efficiency
• High MTBF
• IEC320 AC input receptacle 3 pin (type C6) - AD5012N3LM www.DataSheet4U.com 2 pin (type C8) - AD5012N2LM
• Built in EMI filter
• (CISPR 22 Class B)
• AC input fuse
• Complies with One Watt Input Energy Star / Blue Angel Requirement
• CE Mark EMC & LVD Input Input ra­nge: Frequency: Inrush current: Input current: Efficiency: EMI/RFI: Safety ground leakage current: 90-264 Vac (wide range) 47-63 Hz 60A maximum @ 230VAC, col...

Datasheet PDF File AD5012N2LM Datasheet - 881.86KB

AD5012N2LM   AD5012N2LM  





Similar Datasheet

Part Number Description
AD5012N2L
manufacturer
Emerson
AC-DC / External Freestanding Adapter
Embedded Power for Business-Critical Continuity AD50 Series 50 Watts Total Power: Input Voltage: # of Outputs: 50 Watts 90 - 264 VAC Single Rev. 09.19.08_107 AD50 Series  of 2 Electrical Specifications Input Special Features • Universal AC input • Fully regulated output • EN61000-3-2 compliant • Input power <74 watts • Overcurrent and overvoltage protection • High efficiency • High MTBF • IEC320 AC input receptacle 3 pin (type C6) - AD5012N3L www.DataSheet4U.com 2 pin (type C8) - AD5012N2L • Built in EMI filter • (CISPR 22 Class B) • AC input fuse • Complies with One Watt Input Energy Star / Blue Angel Requirement • CE Mark EMC & LVD Input ra­nge: Frequency: Inrush current: ...


MOSFET transistor
MOSFET transistor semiconductor datasheet search & download | Privacy Policy & Contact